NTS - Nippon Tokushu Sokki
โหลดเซลล์จากแบรนด์ญี่ปุ่น

Digital Indicator

Model : ND-7660
What's for
Digital display is an indicator, connecting with all kind of strain gauge load cells, force transducer, such as compressing load cell, tension load cell and torque load cell, excepting of showing the weighing force, the RS-232 interface and 4~20mA output is available for option.
  • Range of Gain Adjustment : Full scale setting of 0.5mV/V~2.5mV/V
  • Value Display Range : ±10000
  • Linearity : 0.05% of F.S.±digit
  • A/D Converter : 16 bit 640 times/sec.
  • LED Lamp : 4 lamps Red (HI, LOW) Green (OK) Yellow (HOLD)
  • Key switch : 4 switches ZERO, MENU, RESET, HOLD
  • Compare function : Top/bottom value setting
  • HOLD function :
    - Peak, bottom, signal from outer appliances, peak or bottom 
    - data in limited area, limited period top point or change point
  • Output signal : Open collector O.L, HI, OK, LOW
  • Input signal : Contact point or open collector ZERO, HOLD, RESET
  • Outer Power Supply : DC24V for input/output signal isolation
  • Optional Models : 
    - Indicator unit with RS-232C interface
    - Indicator unit with analog output 4-20mA
  • Power Supply: AC 85V~265V
  • Operation Condition : 
    - Temperatire : 5~40°C
    - Humidity less than 85%RH (No bedewing)
  • Outer Dimension : 96W*96H*155Dmm (Panel cut 92*92mm)
  • Weight : Approx. 900g

Portable Display

Model : HF-E
What's for
HF-E series is display type force gauge for connecting external load cell. Various size, types and shapes of load cell can be connected and utilized with the same functions as HF series performed.
  • Measurment Unit  : N, Kgf, (gf), lbf
  • Accuracy : ±0.2% F.S.
  • Repeatability : ±0.1% F.S.
  • Response speed : 10~320HZ, 6 Steps
  • Display : 4Digit LCD Display
  • Measurement : Maximum Value • Moment Value
  • Sampling : 640 Times Per Sec.
  • Allowable Load : 150% (Alarm Buzzer At 105%)
  • A/D Converter : A/D Converter 16bit
  • Operation Time : Approx.10 Hours (Full Charged At 25℃)
  • Charging Time : Approx.6 Hours
  • Opertion Temperature : 0~+40℃
  • Power :     
    - NI-MH Battery,
    - A/C Adaptor For Charging (110V,220V)
  • Weight : 500g
  • Dimensions : 230x65x35mm
  • Standard Accessaries : Attachment, A/C Adapter, Cables, Case
  • Output : 
    - Standardanalog Output ±2V F.S.
    - Optionalprinter Connecting, Digimatic Output,
    - CEntronics Interface. Comparator Connecting,
    - RS-232 Interface.

Load Cell Amplifier

Model : AL-168
What's for

AL-168 signal strain gauge Amplifier is load cell amplifier, used to connect with strain gauge load cells, such as s type load cell, s beam load cell, tension load cell, button load cell, torque load cell... etc.

The Amplifier output is 0 ~ ±10V. Zero offset range is ±0.25mV/V. Nonlinearity accuracy is ± 0.02% of Full Scale.

  • Applied converter : Strain gauge type transducer
  • Bridge voltage : DC2.5V, DC5V, DC10V (within 30mA)
  • Rated output : Voltage ±10V
  • Zero adjust range : ±0.25mV/V(input conversion)
  • Sensitivity adjust Range(input sensitivity) : 
  • - Type L : output 10V for input 1.00mV/V~5.00mV/V
  • - Type M : output 10V for input 0.50mV/V~2.50mV/V
  • - Type H : output 10V for input 0.35mV/V~0.70mV/V
  • Calibration value : 0.25mV/V, 0.5mV/V, 1mV/V(accuracy within ± 2%)
  • Terminal joint : 7.62mm pitch, M3 × L6, + head screw
  • Response frequency : Vessel type low bus. Filter 2Hz(-3db) 10Hz(-3db) 100Hz(-3db) 1kHz(-3db)
  • Nonlinearity : Within 0.02% F.S.
  • Influenced by temp. variation Movement of zero point Sensitivity variation
  •  : Within 1 μ V/℃(input conversion) Within 0.1%F.S./℃
  • Used in temperature : -10 ~ 60℃
  • Electric power source : AC100V ± 10%, 50/60Hz, about 5VA (AC 220V is available)
  • Weight : About 700g
  • Dimensions(outside) : 44W × 92H × 110D without jutty

Torque Sensor for static

Model : TCF-Series
What's for

t is a non rotary type torsion transducer, a toque strain gauge load cell and sensor.

The torsion is from 0.2N ~ 5000N, widely used in the automatic torsion tester and all kind of torsion checker.

  • Rated Capacity : 0.2Nm~5000N-m
  • Rated Output : 1mV/V±1%(0​​.2Nm is 0.7mV/V)
  • Non-Linearity : 0.3% RO (0.2Nm~5N-m is 0.5%R.O.)
  • Hysteresis : 0.3% RO (0.2Nm~5N-m is 0.5%R.O.)
  • Repeatability : 0.2% R.O.
  • Recommended Input Voltage : 10V
  • Maximum Input Voltage : 18V
  • Input / Output Resistance : 350Ω±1%
  • Insulation Resistance : >2000MΩ
  • Temperature Effect on Zero Balance : ±0.0105%R.O./ ℃
  • Temperature Effect on Rated Output : ±0.01%/℃
  • Safe Overload Rating : 120%R.C.
  • Cable :     
    - ∮10、4-conductor shielded cable, Length 3m (500N-m and above)
    - ∮6、4-conductor shielded cable, Length 2m(1~200N-m)
    - ∮3、4-conductor shielded cable, Length 2m (0.2~0.5Nm)
Image

Compression Load Cell

Model : LCH-Series
What's for

It is a hydraulic load cell, a strain gauge transducer, LCH load cell is designed for compression force.

This force sensor is widely used in the automobile and automatic force measurement industry, suitable to connect with load cell amplifier or strain gague amplifier.

  • Rated Capacity : 5KN〜500KN
  • Rated Output : 1mV/V±1%
  • Non-Linearity : 0.3%R.O.
  • Hysteresis : 0.3%R.O.
  • Repeatability : 0.3%R.O.
  • Recommended Input Voltage : 10V
  • Maximum Input Voltage : 18V
  • Input / Output Resistance : 700Ω±1%(5KN is 350±1%)
  • Insulation Resistance : 2000MΩ以上
  • Compensated Temperature Range : -10~+70℃
  • Operating Temperature Range : -20~+100℃
  • Temperature Effect on Zero Balance : ±0.01%R.O./℃
  • Temperature Effect on Rated Output : ±0.01%/℃
  • Safe Overload Rating : 120%R.C.
  • Cable : ∮6、4-conductor shielded cable 3m long
Image

Miniature Compression Load Cell

Model : LCS-Series
What's for

Miniature load cell is a button load cell, small size, mainly used in limited space.

It is a stain gauge type load cell, for compresion application.

This strain gauge trasnducer's capacity is from 10N to 1KN, suitable to connect with load cell amplifier or strain gague amplifier.

LCS
  • Specifications Capacity : 10N〜1KN
  • Output Voltage : About 1mv/v(10n~50n is 0.5mv/v)
  • Non-linear : 0.5%R.O.
  • Hysteresis : 0.5%R.O.
  • Recommended Input Voltage : 5V
  • Maximum Input Voltage : 10 V
  • Input / Output Resistance : 350Ω±1%
  • Safe Overload Rating : 120%R.C.
  • Cable : ¢3.4-conductor shielded cable 5m long
  • Weight : About 75g
LCS-L
  • Specifications Capacity : 1KN〜10KN
  • Output Voltage : About 1mv/v
  • Non-linear : 1%R.O.
  • Hysteresis : 1%R.O.
  • Recommended Input Voltage : 5V
  • Maximum Input Voltage : 10 V
  • Input / Output Resistance : 350Ω
  • Safe Overload Rating : 120%R.C.
  • Cable : ¢3.4-conductor shielded cable 5m long
  • Weight : About 70g
LCS-H
  • Specifications Capacity : 5KN〜30KN
  • Output Voltage : About 1mv/v
  • Non-linear : 2%R.O.
  • Hysteresis : 2%R.O.
  • Recommended Input Voltage : 5V
  • Maximum Input Voltage : 10 V
  • Input / Output Resistance : 350Ω
  • Safe Overload Rating : 120%R.C.
  • Cable : ¢3.4-conductor shielded cable 5m long
  • Weight : About 85g
Image

Pancake Load Cell

Model : LCX-Series
What's for

LCX force transducer is a high accuracy strain gauge load cell, mainly for compression force.

Low profile, high accuracy of ±0.05% tolerance, sensoring the range from 5kN ~ 2000kN, widely used in all kind of weighing and force measurement industries, specially for automobile and automatic assembly machine, suitable to connect with load cell amplifier or strain gague amplifier.

  • Rated Capacity : 5KN~200KN
  • Rated Output : 2mV/V±0.25%
  • Non-Linearity : 0.05% R.O.
  • Hysteresis : 0.05% R.O.
  • Repeatability : 0.03% R.O.
  • Recommended Input Voltage : 10V
  • Maximum Input Voltage : 18V
  • Input / Output Resistance : 350Ω±1%
  • Insulation Resistance : >2000MΩ
  • Compensated Temperature Range : -10~+70℃
  • Operating Temperature Range : -20~+100℃
  • Temperature Effect on Zero Balance : ±0.005%R.O./℃
  • Temperature Effect on Rated Output : ±0.005%/℃
  • Safe Overload Rating : 150%R.C.
  • Cable : ∮10、4-conductor shielded cable 3m long
Image

Tension Compression Load Cell

Model : LRM-Series
What's for

LRM force transducer is a high accuracy strain gauge load cell, for push and pull force measurement.

High accuracy of ±0.05% tolerance, sensor the range from 10N ~ 20KN, widely used in all kind of weighing and force measuring industries, suitable to connect with load cell amplifier or strain gague amplifier.

  • Rated Capacity : 10KN~20KN
  • Rated Output : 2mV/V±1%(10N-50N is 1m/V/V,100N is 1.5mV/V
  • Non-Linearity : 0.05% R.O.
  • Hysteresis : 0.05% R.O.
  • Repeatability : 0.05% R.O.
  • Recommended Input Voltage : 10V(10N~50N is 5V)
  • Maximum Input Voltage : 18V(10N~50N is 10V)
  • Input / Output Resistance : 350Ω±1%
  • Insulation Resistance : 2000MΩ以上
  • Compensated Temperature Range : -10~+70℃
  • Operating Temperature Range : -20~+100℃
  • Temperature Effect on Zero Balance : ±0.01%R.O./℃
  • Temperature Effect on Rated Output : ±0.01%/℃
  • Safe Overload Rating : 120%R.C.
  • Cable : ∮6、4-conductor shielded cable 2m long 5KN or more, length 3m
Image

Tension and Compression Load Cell

Model : LRK-Series
What's for

LRK force transducer is a s beam or s type load cell, high accuracy load cell, for pull test, and compression test.

High accuracy of ±0.05% tolerance, sensoring the range from 10N ~ 20KN, This strain gauge load cell is widely used in all kind of weighing and force measuring industries, suitable to connect with load cell amplifier or strain gague amplifier.

  • Rated Capacity : 10KN~20KN
  • Rated Output : 2mV/V±1%(100N-200N is ±3%
  • Non-Linearity : 0.05% R.O.
  • Hysteresis : 0.05% R.O.
  • Repeatability : 0.03% R.O.
  • Recommended Input Voltage : 10V(100N~200N is 5V)
  • Maximum Input Voltage : 18V(100N~200N is 10V)
  • Input / Output Resistance : 350Ω±1%
  • Insulation Resistance : >2000MΩ
  • Compensated Temperature Range : -10~+70℃
  • Operating Temperature Range : -20~+100℃
  • Temperature Effect on Zero Balance : ±0.01%R.O./℃
  • Temperature Effect on Rated Output : ±0.01%/℃
  • Safe Overload Rating : 120%R.C.
  • Cable : 
    - ∮6、4-conductor shielded cable 3m long(500N~20KN)
    - ∮3、4-conductor shielded cable 3m long(100N~200N)
Image

Weighing Indicator

Model : NTS-4840
What's for
2000 times / second high-speed sampling, auto-zero, the lower output, the peak capture, a variety of output.
  • Model : NTS-4840
  • Bridge voltage : DC2.5V, DC5V free to switch
  • Signal Input Range : ±0.25 mV / V~3mV / V(A voltage is applied 5V) ±0.5 mV / V~3 mV / V(A voltage is applied 2.5 V)
  • Zero range : When the sensitivity correction: inverter rated output of about 50%, after the correction: Correction within the scope of any of (auto-zero)
  • Frequency response : 3Hz,10Hz,30Hz,100 Hz,300Hz,1KHz
  • Sampling rate : 2000 times / second
  • Display Range : -9999至9999
  • Linearity : 0.05%F.S.±1Digit
  • Zero drift : ±0.5μV /℃(Typ.)
  • Full scale drift : 0.02% F.S ± 1 digit or less
  • Correction mode : Digital calibration or correction weights
  • Sync : Peak hold, sample and hold
  • Output method : 2 group alarm relay signals
  • Zero mode : ZERO, external input is cleared
  • Output voltage : ±10 V
  • Power supply : AC85V~264V 50/60Hz(約20VA)
  • Operating temperature range : 5 ℃ ~ 40 ℃, 85% RH or less

สินค้าแนะนำสำหรับคุณ

> Force Gauge & Test Stand
> Force Gauge & Test Stand
เครื่องทดสอบแรงดึงแรงกด แบบพกพา
See More
> Leak Test Chamber
> Leak Test Chamber
เครื่องทดสอบรอยรั่วของบรรจุภัณฑ์
See More
> Coefficient of Friction Tester
> Coefficient of Friction Tester
เครื่องทดสอบสัมประสิทธิ์แรงเสียดทานของวัสดุ
See More